Skip to content
2000
Volume 24, Issue 7
  • ISSN: 1871-5273
  • E-ISSN: 1996-3181

Abstract

Cerebral or brain infarction is a pathological process that restricts or blocks the supply of blood to the brain due to occlusion or narrowing of cerebral blood vessels. At present, computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used to image cerebral infarction. Along with imaging, numerous non-invasive external brain monitoring tools are being developed that use a variety of technologies to act as sensors for neurological disorders, including stroke. This review briefly discussed the recent biomarkers for cerebral infarction and its diagnostic system through different biosensors.

Loading

Article metrics loading...

/content/journals/cnsnddt/10.2174/0118715273372575250212091813
2025-02-14
2025-09-06
Loading full text...

Full text loading...

References

  1. PoncyljuszW. FalkowskiA. KojderI. Treatment of acute ischemic brain infarction with the assistance of local intraarterial thrombolysis with recombinant tissue-type plasminogen activator.Acta Radiol.200748777478010.1080/02841850701408228 17729010
    [Google Scholar]
  2. SubramaniamS. HillM.D. Massive cerebral infarction.Neurologist200511315016010.1097/01.nrl.0000159987.70461.d7 15860137
    [Google Scholar]
  3. WalshK.B. Non-invasive sensor technology for prehospital stroke diagnosis: Current status and future directions.Int. J. Stroke201914659260210.1177/1747493019866621 31354081
    [Google Scholar]
  4. KwonH. KimK. JoY.H. Early detection of cerebral infarction with middle cerebral artery occlusion with functional near-infrared spectroscopy: A pilot study.Front. Neurol.2018989810.3389/fneur.2018.00898 30467489
    [Google Scholar]
  5. ZhangX. GuoT. WangH. Potential biomarkers of acute cerebral infarction detected by SELDI-TOF-MS.Am. J. Clin. Pathol.2008130229930410.1309/CA242R5VY14HUGE8 18628101
    [Google Scholar]
  6. BaezS.C. García del BarcoD. Hardy-SosaA. Scalable bio marker combinations for early stroke diagnosis: A systematic review.Front. Neurol.20211263869310.3389/fneur.2021.638693 34122297
    [Google Scholar]
  7. GlushakovaO. GlushakovA. MillerE. ValadkaA. HayesR. Biomarkers for acute diagnosis and management of stroke in neurointensive care units.Brain Circ.201621284710.4103/2394‑8108.178546 30276272
    [Google Scholar]
  8. AppiahD. FashanuO.E. HeckbertS.R. CushmanM. PsatyB.M. FolsomA.R. Relation of coagulation factor XI with incident coronary heart disease and stroke.Blood Coagul. Fibrinol201728538939210.1097/MBC.0000000000000616 28009647
    [Google Scholar]
  9. ZhangH. GopinathS.C.B. HuY. Spinal cord injury immunosensor: Sensitive detection of S100β on interdigitated electrode sensor.Heliyon202399e1930410.1016/j.heliyon.2023.e19304 37662784
    [Google Scholar]
  10. HarpazD. KohB. MarksR.S. SeetR.C.S. AbdulhalimI. TokA.I.Y. Point-of-care surface plasmon resonance biosensor for stroke biomarkers NT-proBNP and s100β using a functionalized gold chip with specific antibody.Sensors20191911253310.3390/s19112533 31163612
    [Google Scholar]
  11. LeeJ. HiranoH. TsugawaW. SodeK. Development of an Electrochemical Biosensor of Ubiquitin C-Terminal Hydrolase L1 (UCH-L1) for the Assessment of Traumatic Brain Injury (TBI). ECS Meet Abst202002442784410.1149/MA2020‑02442784mtgabs
    [Google Scholar]
  12. WangX. ZhangJ. QinD. Highly sensitive biosensor for neuron-specific enolase detection with bovine-serum-albumin doped graphene field-effect transistor.IEEE Sens. J.20232312124701247610.1109/JSEN.2023.3265069
    [Google Scholar]
  13. KaramanC. BölükbaşıÖ.S. YolaB.B. KaramanO. AtarN. YolaM.L. Electrochemical neuron-specific enolase (NSE) immunosensor based on CoFe2O4@Ag nanocomposite and AuNPs@MoS2/] rGO.Anal. Chim. Acta2022120033960910.1016/j.aca.2022.339609 35256133
    [Google Scholar]
  14. LakshmipriyaT. FujimakiM. GopinathS.C.B. AwazuK. HoriguchiY. NagasakiY. A high-performance waveguide-mode biosensor for detection of factor IX using PEG-based blocking agents to suppress non-specific binding and improve sensitivity.Analyst2013138102863287010.1039/c3an00298e 23577343
    [Google Scholar]
  15. GongW SunM GuoX LiuY LiH XieL Nanowired dual-electrodes surface to monitor cerebral ischemia by currentvolt measurements. 3 Biotech20211150210.1007/s13205‑021‑03048‑4
  16. NovodchukI. KayaharmanM. AusriI.R. An ultrasensitive heart-failure BNP biosensor using B/N co-doped graphene oxide gel FET.Biosens. Bioelectron.202118011311410.1016/j.bios.2021.113114 33676163
    [Google Scholar]
  17. AgostiniM. AmatoF. VieriM.L. Glial-fibrillary-acidic-protein (GFAP) biomarker detection in serum-matrix: Functionalization strategies and detection by an ultra-high-frequency surface-acoustic-wave (UHF-SAW) lab-on-chip.Biosens. Bioelectron.202117211277410.1016/j.bios.2020.112774 33160234
    [Google Scholar]
  18. Adrover-JaumeC. Alba-PatiñoA. ClementeA. Paper biosensors for detecting elevated IL-6 levels in blood and respiratory samples from COVID-19 patients.Sens. Actuat B Chem.202133012933310.1016/j.snb.2020.129333 33519090
    [Google Scholar]
  19. LeeJ. YunJ.Y. LeeW.C. A reference electrode-free electrochemical biosensor for detecting MMP-9 using a concentric electrode device.Sens. Actuat B Chem.201724073574110.1016/j.snb.2016.09.026
    [Google Scholar]
  20. KimJ. ParkJ.A. YimG. Fabrication of an electrochemical biosensor composed of multi-functional Ag ion intercalated DNA four-way junctions/rhodium nanoplate heterolayer on a micro-gap for C-reactive protein detection in human serum.Analyst202114672131213710.1039/D0AN02135K 33861260
    [Google Scholar]
/content/journals/cnsnddt/10.2174/0118715273372575250212091813
Loading
/content/journals/cnsnddt/10.2174/0118715273372575250212091813
Loading

Data & Media loading...


  • Article Type:
    Review Article
Keyword(s): biomarker; biosensor; brain; Cerebral infarction; ischemic stroke; S100β
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test