Skip to content
2000
Volume 13, Issue 4
  • ISSN: 1872-2113
  • E-ISSN: 2212-4039

Abstract

Background: Excessive blue light light-emitting diode (LED) exposure and consequent oxidative stress causes corneal damage and corneal injuries are the major problem arising these days due to excessive use of mobile phone, TV, environment pollution, etc. Objective: In the present investigation, the protectiveness of carboxymethyl Terminalia catappa (CTC) from blue light LED-induced corneal damage was explored. Methods: For this purpose, Terminalia catappa (TC) was functionalized by carboxymethylation and its structural modification was confirmed by spectral attributes. Further, the CTC protective eye drop formulations (0.025-1%, w/v) were prepared and evaluated for their capability of protection from blue light LEDinduced corneal damage as compared to CTC protective eye gel (1.25-7%, w/v). The findings pointed towards excellent protection of CTC gel formulations as compared to CTC eye drop formulations. In addition, the prepared optimized CTC gel had thixotropic behavior as evident from percentage structural recovery which was 1.75 fold higher than marketed formulation (I-Comfort, HPMC 2%, w/v). The safety and non-toxicity of CTC protective eye drop and gel were confirmed by HET-CAM test. Further, a rat eye model was implemented that mimic blue light light-emitting diode induced corneal damage in day to day life to assess the protective effect of CTC protective eye drop and gel. Results: The order of protectiveness of CTC formulations was found to be CTC protective eye gel (4%, w/v) (no corneal damage)>marketed eye gel (12.34% corneal damage)=CTC protective eye drop (0.75%, w/v) (17.48% corneal damage)> marketed eye drop (51% corneal damage). The mechanism behind the protective effect of CTC eye drop and gel was associated with good free radical scavenging activity and corneal adhesive property of CTC. It is established from the present work that, carboxymethyl Terminalia catappa has protective action against blue light light-emitting diode induced corneal damage.

Loading

Article metrics loading...

/content/journals/ddf/10.2174/1872211314666191218110440
2019-12-01
2025-09-10
Loading full text...

Full text loading...

/content/journals/ddf/10.2174/1872211314666191218110440
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test