Skip to content
2000
image of 
The Use of Portable Device for Measuring Nasal FeNO in Subjects with Allergic Rhinitis - A Single Center Study

Abstract

Objective

This study aimed to demonstrate the accuracy of a portable device for measuring nasal and bronchial fractional exhaled nitric oxide (nFeNO and FeNO) as an alternative method to replace a high-cost multiple flow device in subjects with allergic rhinitis (AR).

Methods

It was a descriptive and comparative study. The healthy subjects (control group), subjects with AR (AR group) and those with AR and asthma (AR-A group) were enrolled in this study. They underwent nasal and bronchial FeNO measurements by both fixed flow NObreath®connected to nasal mask (for nFeNO) and without mask (for FeNO) and multiple flows HypAir FeNO®.

Results

There were 153 subjects recruited during the study period, including 63 healthy subjects and 90 subjects with AR and AR-A. There were no statistically significant differences in anthropometric characteristics between study groups. The concentrations of nasal FeNO and bronchial FeNO measured by a portable device in subjects with AR were higher than in healthy subjects: 76.0 ± 50.7 ppb vs 36.0 ± 28.1 ppb ( < 0.01), and 32.3 ± 15.4 ppb vs 9.2 ± 5.6 ppb ( < 0.001). There was a weak correlation between nasal FeNO measured by portable devices and multiple flow devices.

Conclusions

The portable device is useful in measuring nasal FeNO in subjects with AR. The advantages of a low-cost and accurate portable device may help it be used in primary care in the management of subjects with allergic rhinitis and asthma.

Loading

Article metrics loading...

/content/journals/crmr/10.2174/011573398X339992241225195222
2025-01-24
2025-10-02
Loading full text...

Full text loading...

References

  1. Gustafsson L.E. Leone A.M. Persson M.G. Wiklund N.P. Moncada S. Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans. Biochem. Biophys. Res. Commun. 1991 181 2 852 857 10.1016/0006‑291X(91)91268‑H 1721811
    [Google Scholar]
  2. Lundberg J.O.N. Farkas-Szallasi T. Weitzberg E. Rinder J. Lidholm J. Änggåard A. Hökfelt T. Lundberg J.M. Alving K. High nitric oxide production in human paranasal sinuses. Nat. Med. 1995 1 4 370 373 10.1038/nm0495‑370 7585069
    [Google Scholar]
  3. Abba A. Exhaled nitric oxide in diagnosis and management of respiratory diseases. Ann. Thorac. Med. 2009 4 4 173 181 10.4103/1817‑1737.56009 19881162
    [Google Scholar]
  4. Vo-Thi-Kim A. Van-Quang T. Nguyen-Thanh B. Dao-Van D. Duong-Quy S. The effect of medical treatment on nasal exhaled nitric oxide (NO) in patients with persistent allergic rhinitis: A randomized control study. Adv. Med. Sci. 2020 65 1 182 188 10.1016/j.advms.2019.12.004 31978697
    [Google Scholar]
  5. Duong-Quy S. Hua-Huy T. Tran-Mai-Thi H.T. Le-Dong N.N. Craig T.J. Dinh-Xuan A.T. Study of exhaled nitric oxide in subjects with suspected obstructive sleep apnea: a pilot study in vietnam. Pulm. Med. 2016 2016 1 7 10.1155/2016/3050918 26881073
    [Google Scholar]
  6. Tee K.H. Hui K.P. ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005. Am. J. Respir. Crit. Care Med. 2005 171 8 912 930 10.1164/rccm.200406‑710ST 15817806
    [Google Scholar]
  7. Dweik R.A. Boggs P.B. Erzurum S.C. Irvin C.G. Leigh M.W. Lundberg J.O. Olin A.C. Plummer A.L. Taylor D.R. An official ATS clinical practice guideline: interpretation of exhaled nitric oxide levels (FENO) for clinical applications. Am. J. Respir. Crit. Care Med. 2011 184 5 602 615 10.1164/rccm.9120‑11ST 21885636
    [Google Scholar]
  8. Maniscalco M. Vitale C. Vatrella A. Molino A. Bianco A. Mazzarella G. Fractional exhaled nitric oxide-measuring devices: technology update. Med. Devi. 2016 9 151 160 10.2147/MDER.S91201 27382340
    [Google Scholar]
  9. Ragnoli B. Radaeli A. Pochetti P. Kette S. Morjaria J. Malerba M. Fractional nitric oxide measurement in exhaled air (FeNO): perspectives in the management of respiratory diseases. Ther. Adv. Chronic Dis. 2023 14 20406223231190480 10.1177/20406223231190480 37538344
    [Google Scholar]
  10. Weschta M. Deutschle T. Riechelmann H. Nasal fractional exhaled nitric oxide analysis with a novel hand-held device. Rhinology 2008 46 1 23 27 18444488
    [Google Scholar]
  11. Duong-Quy S. Clinical utility of the exhaled nitric oxide (NO) measurement with portable devices in the management of allergic airway inflammation and asthma. J. Asthma Allergy 2019 12 331 341 10.2147/JAA.S190489 31632093
    [Google Scholar]
  12. Takeno S. Okabayashi Y. Kohno T. Yumii K. Hirakawa K. The role of nasal fractional exhaled nitric oxide as an objective parameter independent of nasal airflow resistance in the diagnosis of allergic rhinitis. Auris Nasus Larynx 2017 44 4 435 441 10.1016/j.anl.2016.09.007 27692400
    [Google Scholar]
  13. Duong-Quy S. Vu-Minh T. Hua-Huy T. Tang-Thi-Thao T. Le-Quang K. Tran-Thanh D. Doan-Thi-Quynh N. Le-Dong N.N. Craig T.J. Dinh-Xuan A.T. Study of nasal exhaled nitric oxide levels in diagnosis of allergic rhinitis in subjects with and without asthma. J. Asthma Allergy 2017 10 75 82 10.2147/JAA.S129047 28356764
    [Google Scholar]
  14. Nur Husna S.M. Tan H.T.T. Md Shukri N. Mohd Ashari N.S. Wong K.K. Allergic rhinitis: a clinical and pathophysiological overview. Front. Med. 2022 9 874114 10.3389/fmed.2022.874114 35463011
    [Google Scholar]
  15. Wang I.J. Tung T.H. Tang C.S. Zhao Z.H. Allergens, air pollutants, and childhood allergic diseases. Int. J. Hyg. Environ. Health 2016 219 1 66 71 10.1016/j.ijheh.2015.09.001 26404109
    [Google Scholar]
  16. Fröhlich M. Pinart M. Keller T. Reich A. Cabieses B. Hohmann C. Postma D.S. Bousquet J. Antó J.M. Keil T. Roll S. Is there a sex-shift in prevalence of allergic rhinitis and comorbid asthma from childhood to adulthood? A meta-analysis. Clin. Transl. Allergy 2017 7 1 44 10.1186/s13601‑017‑0176‑5 29225773
    [Google Scholar]
  17. Duong-Quy S. Nguyen-Thi-Dieu T. Tran-Quang K. Tang-Thi-Thao T. Nguyen-Van T. Vo-Pham-Minh T. Vu-Tran-Thien Q. Bui-Diem K. Nguyen-Nhu V. Hoang-Thi L. Craig T. Study of nasal fractional exhaled nitric oxide (FENO) in children with allergic rhinitis. Sinusitis 2021 5 2 123 131 10.3390/sinusitis5020013
    [Google Scholar]
  18. Cho W.S. Kim T.H. Kim K.H. Lee H.M. Lee S.H. Ju Y.H. Park E.H. Kim K.W. Lee S.H. Increased expression of arginase I and II in allergic nasal mucosa. Laryngoscope 2011 121 2 236 240 10.1002/lary.21288 21271567
    [Google Scholar]
  19. Hood CM Schroter RC Doorly DJ Blenke EJ Tolley NS Computational modeling of flow and gas exchange in models of the human maxillary sinus. J. Appl. Physiol. 1985 107 4 1195 1203 10.1152/japplphysiol.91615.2008 19608923
    [Google Scholar]
  20. Bautista A.P. Eisenlohr C.P. Lanz M.J. Nasal nitric oxide and nasal eosinophils decrease with levocetirizine in subjects with perennial allergic rhinitis. Am. J. Rhinol. Allergy 2011 25 6 383 387 10.2500/ajra.2011.25.3668 22185740
    [Google Scholar]
  21. Nesic V.S. Djordjevic V.Z. Tomic-Spiric V. Dudvarski Z.R. Soldatovic I.A. Arsovic N.A. Measuring nasal nitric oxide in allergic rhinitis patients. J. Laryngol. Otol. 2016 130 11 1064 1071 10.1017/S0022215116009087 27823578
    [Google Scholar]
  22. Korn S. Telke I. Kornmann O. Buhl R. Measurement of exhaled nitric oxide: Comparison of different analysers. Respirology 2010 15 8 1203 1208 10.1111/j.1440‑1843.2010.01847.x 20920124
    [Google Scholar]
  23. Pisi R. Aiello M. Tzani P. Marangio E. Olivieri D. Chetta A. Measurement of fractional exhaled nitric oxide by a new portable device: comparison with the standard technique. J. Asthma 2010 47 7 805 809 10.3109/02770903.2010.485667 20670207
    [Google Scholar]
  24. Heffler E. Carpagnano G.E. Favero E. Guida G. Maniscalco M. Motta A. Paoletti G. Rolla G. Baraldi E. Pezzella V. Piacentini G. Nardini S.G. Fractional exhaled nitric oxide (FENO) in the management of asthma: a position paper of the italian respiratory society (SIP/IRS) and italian society of allergy, asthma and clinical immunology (SIAAIC). Multidiscip. Respir. Med. 2020 15 1 36 10.4081/mrm.2020.36 32269772
    [Google Scholar]
  25. Nerpin E. Olivieri M. Gislason T. Olin A.C. Nielsen R. Johannessen A. Ferreira D.S. Marcon A. Cazzoletti L. Accordini S. Pin I. Corsico A. Demoly P. Weyler J. Nowak D. Jõgi R. Forsberg B. Zock J.P. Sigsgaard T. Heinric J. Bono R. Leynaert B. Jarvis D. Janson C. Malinovschi A. Determinants of fractional exhaled nitric oxide in healthy men and women from the european community respiratory health survey III. Clin. Exp. Aller. 2019 49 7 969 979 10.1111/cea.13394 30934155
    [Google Scholar]
  26. Antus B. Horvath I. Barta I. Assessment of exhaled nitric oxide by a new hand-held device. Respir. Med. 2010 104 9 1377 1380 10.1016/j.rmed.2010.06.005 20594818
    [Google Scholar]
  27. Rawy A.M. Measurement of exhaled nitric oxide in healthy Egyptian population: normal ranges and factors affecting. Egypt. J. Bronchol. 2015 9 1 48 54 10.4103/1687‑8426.153599
    [Google Scholar]
  28. Saito J. Kikuchi M. Fukuhara A. Sato S. Rikimaru M. Suzuki Y. Uematsu M. Fukuhara N. Kawamata T. Umeda T. Togawa R. Sato Y. Koizumi T. Hirai K. Minemura H. Nikaido T. Kanazawa K. Tanino Y. Shibata Y. Munakata M. Comparison of fractional exhaled nitric oxide levels measured by different analyzers produced by different manufacturers. J. Asthma 2020 57 11 1216 1226 10.1080/02770903.2019.1642351 31288573
    [Google Scholar]
  29. Kawamoto H. Takeno S. Yajin K. Increased expression of inducible nitric oxide synthase in nasal epithelial cells in patients with allergic rhinitis. Laryngoscope 1999 109 12 2015 2020 10.1097/00005537‑199912000‑00023 10591366
    [Google Scholar]
  30. Inoue Y. Sato S. Manabe T. Makita E. Chiyotanda M. Takahashi K. Yamamoto H. Yanagida N. Ebisawa M. Measurement of exhaled nitric oxide in children: A comparison between no breath ® and Niox Vero ® analyzers. Allergy Asthma Immunol. Res. 2018 10 5 478 489 10.4168/aair.2018.10.5.478 30088368
    [Google Scholar]
  31. Högman M. Bowerman C. Chavez L. Dressel H. Malinovschi A. Radtke T. Stanojevic S. Steenbruggen I. Turner S. Dinh-Xuan A.T. ERS technical standard: Global lung function initiative reference values for exhaled nitric oxide fraction (FENO50). Eur. Respir. J. 2024 63 1 2300370 10.1183/13993003.00370‑2023 37973177
    [Google Scholar]
/content/journals/crmr/10.2174/011573398X339992241225195222
Loading
/content/journals/crmr/10.2174/011573398X339992241225195222
Loading

Data & Media loading...


  • Article Type:
    Research Article
Keywords: bronchial FeNO ; portable device ; Fractional exhaled nitric oxide ; nasal FeNO
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test