Abstract

Objective: A particular, easy, and precise reverse phase liquid chromatographic technique was developed for the determination of Zaltoprofen in human plasma. Methods: The ODS C18 (250mm x 4.6mm, 5μm) column was utilized for determination. The mobile phase contains buffer and acetonitrile (55:45 v/v). The rate of flow was 1.0 ml/min. The volume of infused sample was 10 μl. The column was kept at a temperature of ~30°C and equilibrated for no less than 30 min, prior to injection of the solutions. The detection wavelength was set at 331 nm. Results: The linearity experiment was performed for Zaltoprofen in the range of 0.15 to 20 μg/ml. The observed recovery of Zaltoprofen was 98.32 %. Conclusion: The suggested technique has been validated and has proved to be very helpful for zaltoprofen determination in human plasma.

Loading

Article metrics loading...

/content/journals/cpa/10.2174/1573412916999200409105530
2021-07-01
2025-10-08
Loading full text...

Full text loading...

/content/journals/cpa/10.2174/1573412916999200409105530
Loading

  • Article Type:
    Research Article
Keyword(s): buffer; human plasma; method; NSAID; validation; Zaltoprofen