Skip to content
2000
Volume 14, Issue 3
  • ISSN: 1573-4129
  • E-ISSN: 1875-676X

Abstract

Background: Levofloxacin (LVX) is one of the fluoroquinolone antibiotics that possess a wide spectrum of bactericidal activity against both Gram-positive and Gram-negative bacteria. Because of its side effects and its potential towards the development of antibiotic resistance, determination of this antibiotic is very important. New methods which have superior properties than the conventional methods are needed in the determination of pharmaceuticals in different samples. Method: An activated pencil graphite electrode (A-PGE) was prepared and its application in the voltammetric determination of LVX in pharmaceutical samples and body fluids was searched. Results: Oxidation peak currents of LVX were increased 40 times in the presence of A-PGE according to bare PGE. The highest voltammetric response of A-PGE towards LVX was achieved at pH value of 4. A wide linear range (0.01 – 2.5 μM) was observed between the oxidation peak currents and concentrations of LVX. Detection limit was calculated as 0.0075 μM. The inter-day (five days) precision of APGE was found to be 3.16%. Interference studies showed that A-PGE successfully discriminated the voltammetric response of LVX from that of many other structurally related substances such as ciprofloxacin, norfloxacin and enoxacin. Prepared A-PGE preserved 87% of its original activity towards LVX after a 2-month storage. Determination of LVX in blood serum, urine and pharmaceuticals was successfully achieved by A-PGE. Conclusion: The prepared A-PGE brings two important advantages. First one is the selective response of A-PGE towards LVX in the presence of other fluoroquinolone antibiotics (ciprofloxacin, enoxacin and norfloxacin). The other is the high sensitivity of A-PGE towards LVX having the detection limit of 0.0075 μM. In addition to the given advantages, its disposable character, low cost, commercial availability and easy preparation of A-PGE make this electrode an important candidate in the fast and accurate determination of LVX.

Loading

Article metrics loading...

/content/journals/cpa/10.2174/1573412913666170317130625
2018-05-01
2025-10-18
Loading full text...

Full text loading...

/content/journals/cpa/10.2174/1573412913666170317130625
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test