Skip to content
2000
Volume 7, Issue 4
  • ISSN: 1573-4129
  • E-ISSN: 1875-676X

Abstract

Three EPMEs based on maltodextrins with different dextrose equivalent (DE) values [I (4.0-7.0), II (13.0-17.0) and III (16.5-19.5)], were designed for the determination of L-vesamicol. The linear concentration ranges of the proposed electrodes were 10-4 - 10-2 mol/L for maltodextrin I-based electrode, 10-5 -10-3 mol/L for maltodextrin II-based electrode and 10-9 - 10-7 mol/L for maltodextrin III-based electrode. The detection limits of the proposed electrodes were 1.34x10-5, 5.0x10-6 and 3.33x10-10 mol/L for maltodextrin I, II and III based electrodes, respectively. The selectivity of EPMEs for L-vesamicol was tested over D-vesamicol, creatine, creatinine and some inorganic ions. The surfaces of the electrodes can be easily renewed by simply polishing on alumina.

Loading

Article metrics loading...

/content/journals/cpa/10.2174/157341211797458069
2011-11-01
2025-10-27
Loading full text...

Full text loading...

/content/journals/cpa/10.2174/157341211797458069
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test